Sealed Lithium Inorganic Electrolyte Cell.
Abstract
A satisfactory sealing procedure is reported for the primary D size cells. Results are reported for the tests of fresh cells under constant current discharge conditions at several selected discharge temperatures. No voltage delay has been observed on the fresh cells within a week at room temperature. The analysis is reported of the thermal conditions of cells discharged at extreme high rate. The maximum safe discharge rate was calculated from the net heating rate data. A good agreement was observed between the predicted and the realized behavior of cells discharged with extreme high rates. A good capacity-rate behavior has been observed of the fresh cells and also of the cells stored for one month at room temperature prior to the discharge test.
Document Details