Cryogenic Mass Flowmeter Development.

Abstract

This technical report summarizes results of additional studies on a cryogenic linear momentum mass flowmeter. The original study was described in Technical Report AFRPL-TR-71-83. Signal rolloff problems encountered in that study were attributed to magnetic interaction between the driver and sensor windings of the dualsyn transducer. In the present study, the transducer, referred to as a mycrosyn, was redesigned to separate driver and sensor windings.