An Analytical Examination of Impedance and Signal Power Levels Along a Multiplex Data Bus

Abstract

Using MIL-STD-1553 (USAF) as a guide in defining a Multiplex Data Bus, this paper presents in graphical form the results of a series of calculations to determine bus impedance, stub impedance, and signal power levels along a Multiplex Data Bus. The paper also discusses the significance of these parameters in MUX Bus operation.