Cavitation Breakdown of a Pump Operating in Water Having a Dilute Polymer Concentration.
Abstract
An experimental program comparing the performance of a single stage axial flow pump operating in both water and a 30 ppm solution of Polyox 301 is discussed in this report. Definitive results demonstrate that higher suction specific speeds at pump breakdown are obtained when pumping a dilute polymer solution. Photographs of pump breakdown are shown for both water and dilute polymer solution.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 20, 1975
- Accession Number
- ADA009825
Entities
People
- Michael L. Billet
- W. S. Gearhart
Organizations
- Pennsylvania State University