EMP Evaluation of Junction Boxes, Junction-Box Covers, and Gaskets
Abstract
This study reports test results from RFI testing of electrical junction boxes with bolt-on covers. A number of cover-gasket configurations were tested. Tests indicate that a large improvement in the shielding effectiveness of junction boxes can be obtained by increasing the number of cover bolts or using a Metex 'combo strip' gasket. A simple field fix that provides a large increase in shielding effectiveness can be made by doubling the number of cover bolts used on the junction boxes.
Document Details
- Document Type
- Technical Report
- Publication Date
- May 01, 1975
- Accession Number
- ADA010631
Entities
People
- D. J. Leverenz
- P. H. Nielsen
- R. G. Mccormack
Organizations
- Construction Engineering Research Laboratory