Advanced Reactants Laser Performance Evaluation.

Abstract

The objective of this work was to provide preliminary laser performance evaluations for several liquid storable, advanced chemical laser reactant systems. Four advanced reactant systems, F2/MAPPGAS/He, F2/C6F6/He, F2/C7H8/He and F2/C7H8/N2 plus one baseline system F2/C2H2/He were evaluated. Lasing powers between 5 and 8 kw were obtained for all helium diluent systems tested. Significantly lower performance (<3 kw) was obtained with nitrogen diluent. It was concluded that all of the reactant systems tested in this program would provide acceptable performance for combustion driven DF chemical lasers. It was recommended that nitrogen diluent not be used for high pressure nozzles except in cases where helium diluent was unacceptable.

Document Details

Document Type
Technical Report
Publication Date
Dec 18, 1975
Accession Number
ADA018627

Entities

People

  • R. A. Ackerman

Organizations

  • TRW Inc.

Tags

DTIC Thesaurus Topics

  • Chemical Lasers
  • Combustion
  • High Pressure
  • Lasers
  • Nitrogen
  • Test And Evaluation

Readers

  • Combustion science or combustion engineering.
  • Materials Science
  • Pulsed Power and Plasma Physics.

Technology Areas

  • Directed Energy
  • Directed Energy - Lasers