Prediction of Paint Performance from a Combination of Accelerated Laboratory Tests

Abstract

The Civil Engineering Laboratory investigated various accelerated laboratory test procedures for use in predicting the long-term performance of paint systems for steel exposed to a marine atmosphere. Accelerated laboratory test procedures included determining the electrical properties of the paint systems on steel panels (AC and DC resistance and AC capacitance), the water vapor permeability of free films of the paint systems, and the performance of the paint systems on steel panels exposed to a wet-and-dry-cycle test procedure. Results of the accelerated laboratory tests on 12 paint systems were correlated with their long-term performance in two different marine atmospheric environments using linear regression analysis.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1975
Accession Number
ADA018954

Entities

People

  • Peter J. Hearst
  • Robert L. Alumbaugh

Organizations

  • Naval Facilities Engineering Service Center

Tags

DTIC Thesaurus Topics

  • Atmospheres
  • Capacitance
  • Civil Engineering
  • Coatings
  • Cyclic Tests
  • Electrical Measurement
  • Electrical Properties
  • Engineering
  • Environment
  • Laboratory Procedures
  • Laboratory Tests
  • Linear Regression Analysis
  • Marine Atmospheres
  • Measurement
  • Regression Analysis
  • Test Methods
  • Water Vapor

Readers

  • Electrical Engineering
  • Materials Science and Engineering.