Measurement of Electrical Ignition Element Composition Mix Using a Gamma Ray Densitometer.

Abstract

Gamma ray measurements of electrical ignition elements containing ignition mixes with varying percentages of ingredients are presented. Correlations with visual observations of x-ray film, chemical analysis, and gamma ray counts are presented. Functional firing test results are also presented to demonstrate the relationship between accuracy of ignition mix, firing current requirements and ignition delay time. Various functional test techniques were explored in order to determine the method best suited for production testing. (Author)

Document Details

Document Type
Technical Report
Publication Date
Jan 01, 1976
Accession Number
ADA019273

Entities

People

  • F. Madarasz
  • Louis G. Derrico

Organizations

  • Picatinny Arsenal

Tags

DTIC Thesaurus Topics

  • Accuracy
  • Chemical Analysis
  • Densitometers
  • Gamma Rays
  • Ignition
  • Ignition Lag
  • Measurement
  • Observation
  • Production
  • X Ray Film
  • X Rays

Fields of Study

  • Physics

Readers

  • Aerospace Test and Evaluation
  • Combustion science or combustion engineering.