A User's Guide to the CSL Vision System.
Abstract
The staff of the Coordinated Science Laboratory at the University of Illinois has developed a moderate resolution, high speed system for inputting images to a computer. The system is capable of a resolution of 504x476 points of eight bits of grey scale each. This resolution can be obtained only by taking multiple pictures. In any one field of scan (16 ms) a picture consisting of 252x238 points of six bits each can be read in. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1976
- Accession Number
- ADA023438
Entities
People
- V. C. Jones
- W. E. Snyder
Organizations
- University of Illinois Urbana–Champaign