Aluminized Firemen's (Fire Proximity) Handwear: A Comparative Study of Dexterity Characteristics.
Abstract
A comparative study of the tactility and dexterity characteristics of several configurations of aluminized firemen's (fire proximity) handwear was conducted. The old standard aluminized firemen's glove was compared with that of the recently adopted two component (glove shell and glove insert) standard and a newly developed experimental prototype, which was prepared in three models (MOD-I, MOD-II and MOD-III) for this study. The manipulatory capabilities of all the gloves were measured against the ungloved or bare hand, and the results indicated that MOD-III of the new experimental prototype exceeded that of the old and new standard and came closest in performance to the ungloved hand.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1976
- Accession Number
- ADA027211
Entities
People
- Dale A. Reins
- Francis S. Andruk
- James C. Shampine