Pershing Destruct Safe and Arm Detonator Electrical Sensitivity and Output Evaluation.

Abstract

This report provides the measured electrical sensitivity, resistance, bridgewire break delay time, output performance, the Langlie mean, all-fire, and no-fire values for the D39A2 detonator used in the PERSHING destruct safe and arm unit. Three lots, each containing 20 detonators, were tested. The values obtained from these tests show that all three lots of detonators meet the specifications required by MIL-STD-331, Miller Research Laboratories drawing No. 175-20005-E, Hercules, Inc. data sheet HD-2162.