The Measurement of Dimensional Stability of Invar Using Strain-Gage Techniques.

Abstract

The use of Micro-Measurements Type WK-00 strain gates for the measurement of the room-temperature dimensional stability of Invar was investigated. One-half inch diameter Invar rods (0.05% C, 36.2% Ni) were subjected to four heat treatments, which had been reported to produce highly stable Invar components. Microstrain measurement system capabilities are outlined in terms of resolution and stability. Detection of plus or minus 0.2 counts per microstrain strain instabilities after 1000 hr is possible with sufficient consideration of adhesives, bridge components, and measurement laboratory temperature stability.

Document Details

Document Type
Technical Report
Publication Date
Aug 09, 1976
Accession Number
ADA029135

Entities

People

  • C. S. Susskind
  • E. G. Wolff

Organizations

  • The Aerospace Corporation

Tags

DTIC Thesaurus Topics

  • Adhesives
  • Detection
  • Diameters
  • Gages
  • Heat Treatment
  • Instability
  • Measurement
  • Measuring Instruments
  • Strain Gages

Readers

  • Infectious Disease/Epidemiology
  • Mathematics or Statistics
  • Superconducting Magnet Technology