Proof Testing of a Candidate Category 3 Suppressive Shield
Abstract
A prototype structure was designed, fabricated, and tested as a candidate suppressive shield for Category 3 applications. The tests indicate complete containment of secondary fragments from press/pelletizing equipment and blast pressure reductions in the range of 70 to 92% at external close-in locations. The shield did not successfully withstand the required proof test of 560 psi side-on blast overpressure at the wall, due to the ejection of three pieces of 10-gauge perforated steel from the outside layer of the vented panels becoming secondary fragments. Color illustrations reproduced in black and white.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1976
- Accession Number
- ADA029791
Entities
People
- D. A. Martin
- G. L. Mckown