Modified AN/PSM-13 for Field Testing BA-4386/PRC-25.

Abstract

Test set, Battery, AN/PSM-13, using the loaded voltmeter technique, was designed to predict minimum remaining capacity for a number of zinc-carbon batteries. When the magnesium Battery BA-4386/PRC-25 was introduced into the military supply system, Test Set Battery AN/PSM-13 was used with this battery but with inaccurate results. A program was established to determine the factors that influence the operation of the AN/PSM-13 with the magnesium Battery BA-4386/PRC-25 and to design and fabricate a modified version of the tester which would adequately test the battery. Two loaded voltage values were selected to predict the battery state-of-charge relative to its use in Radio Set AN/PRC-77. The upper voltage point indicates that at least 85% of the battery's fresh capacity is remaining; the lower point no less than 15%. A reading between the two points indicates the battery has at least 15% of its capacity remaining; however, it could have up to 100%. The results of the evaluation to determine the accuracy of the modified AN/PSM-13 in predicting the capacity remaining in Battery BA-4386/PRC-25 are presented. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jan 01, 1977
Accession Number
ADA037002

Entities

People

  • Donald B. Wood

Organizations

  • United States Army Communications-Electronics Command

Tags

DTIC Thesaurus Topics

  • Accuracy
  • Connectors
  • Dry Batteries
  • Electronics
  • Fabrication
  • Magnesium
  • Magnesium Batteries
  • Military Supplies
  • New Jersey
  • Resistance
  • Storage
  • Test And Evaluation
  • Test Methods
  • Test Sets
  • Voltage
  • Voltmeters

Readers

  • Aerospace Test and Evaluation
  • Battery Technology and Engineering
  • Computational Modeling and Simulation