A Thermal Imaging Sensor Evaluation Facility.
Abstract
A facility has been developed for testing and evaluating thermal imaging sensors. The facility employs a differential temperature source imaged by a 12 inch off-axis parabolic mirror collimator. The facility can provide differential temperatures ranging from -20C to +80C. Four-bar resolution targets are available from 0.25 cy/mrad to 9.0 cy/mrad. Tests that can be performed include minimum resolvable temperature difference (MRT), signal transfer function (SiTF), modulation transfer function (MTF) and line spread function (LSF), uniformity, and distortion. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jan 01, 1977
- Accession Number
- ADA037411
Entities
People
- Donald V. Campbell Jr.
- Jeffrey P. Johnson
- William R. Mallory