Pulsed-Mode Enclosed-Wire Transducer Analysis.
Abstract
This report contains an analysis and design optimization for pulsed-mode, enclosed-wire transducer. Operating in the pulsed mode, time gating can be used to separate the signals from different portions of a wire-in-tube sensor. A single long transducer and one set of processing electronics can provide multiple range-channel outputs. This study was intended to provide a basis for the subsequent design and feasibility testing of a breadboard sensor.
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1977
- Accession Number
- ADA040105
Entities
People
- C. Tettemer
- L. E. Koehler
- Tanzilur Rahman
Organizations
- Honeywell International, Inc.