Manufacturing Methods and Technology Measure for Arc-Plasma-Sprayed Phase-Shifter Elements.
Abstract
Twenty confirmatory samples and reports were delivered on January 30. Hysteresis loop and microwave testing at Raytheon and confirming measurements at ECOM Laboratories indicate the samples meet or exceed contract requirements. Differential phase shift on 10 test elements averages 384 degrees, compared with the >340 degrees specified. The average insertion loss on these 10 elements was 1.04 dB, which compares with a contract goal of 1 dB or less. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1977
- Accession Number
- ADA040709
Entities
People
- H. J. Van Hook
- R. Maher
Organizations
- RTX