Reaeration Tests, Outlet Works, Beltzville Dam, Pohopoco Creek, Pennsylvania.

Abstract

Prototype water-quality tests were conducted at Beltzville Dam. The purposes of these tests were to: (a) determine the location and degree of reaeration of flow that occurred as it passed through the outlet works, (b) provide prototype data with which to evaluate the accuracy of the selective withdrawal numerical model, SELECT, and (c) supplement results of hydraulic prototype tests conducted at Beltzville Dam in May 1973. Twelve tests were conducted. Temperature and dissolved oxygen data (vertical profiles) were collected upstream of the dam, at seven stations within the outlet structure, and at one station in the downstream channel. The tests involved various flow rates and various outflow port elevations. The results of these prototype tests showed: (a) the dissolved oxygen content of the release flows was approximately 90 to 95 percent of the saturation level regardless of the dissolved oxygen content of the flow entering the structure or the discharge, and major reaeration occurred within the outlet structure downsteam of the water-quality gate; (b) the predictions of the SELECT model were in close agreement with the observed data; and (c) the hydraulic measurements were close to those of the 1973 tests.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jul 01, 1977
Accession Number
ADA043291

Entities

People

  • E. Dale Hart
  • Steven C. Wilhelms

Tags

Communities of Interest

  • Sensors

DTIC Thesaurus Topics

  • Accuracy
  • Air Temperature
  • Chemical Reactions
  • Control Systems
  • Dams
  • Engineers
  • Flood Control
  • Gates
  • Hydraulic Models
  • Instrumentation
  • Measurement
  • Models
  • Stations
  • Stilling Basins
  • Test Facilities
  • Water
  • Water Quality

Readers

  • Environmental Engineering
  • Fluid Dynamics.
  • Hydraulic Engineering.