Hydrotest for FLTSATCOM.
Abstract
On 7 April 1977 AFRPL conducted a hydrostatic burst test of a fired TE-M-364-19 motor case. During testing the case was constrained such that firing conditions were simulated. This test-to-failure demonstrated that the case had a safety factor in excess of the 1.25 minimum. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1977
- Accession Number
- ADA043577
Entities
People
- Richard H. Brown