Propeller Acoustics Test Facility (Capability Description).

Abstract

This report describes the development of a research facility to investigate fan and propeller noise generation mechanisms. A 3500 horsepower electric whirl rig was modified to allow both near- and far-field acoustic testing. The rig is located in a large building with acoustically-treated walls. Reverberation time and sound pressure level measurements were conducted to determine the acoustic characteristics of the building. Acoustic data is acquired using a portable analog FM multichannel tape recorder system. The resultant data is frequency analyzed in one-third octave or narrow bonds. A series of data presentation programs have been developed to cross plot key performance and acoustic parameters. (Author)

Open PDF