Destroyer Engineered Operating Cycle (DDEOC). System Maintenance Analysis FF-1052 Class ASROC Missile Heating and Cooling System and Radar-Sonar Electronic Fresh Water Cooling System SMA 218-728. Review of Experience,

Abstract

This report, the Review of Experience, documents the historical maintenance experience for two FF-1052 Class systems -- the ASROC Missile Heating and Cooling System and the Radar-Sonar Electronic Fresh Water Cooling System. (Author)