Evaluation of 30 kW and 2.5 kW Generators used on SERVPAC ARS and STF Class Ships,

Abstract

An investigation of problems associated with two types of generators used in Navy ARS and ATF class ships is described. Causes of and recommended corrective actions are discussed for failures being experienced by the 30 kW motor generator set, and inadequacies in the emergency communication system utilizing the 2.5 kW diesel generator set. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Nov 01, 1974
Accession Number
ADA051882

Entities

People

  • E. E. Bethke
  • R. N. S. Ho

Organizations

  • ARINC

Tags

Communities of Interest

  • Advanced Electronics
  • Ground and Sea Platforms

DTIC Thesaurus Topics

  • Circuit Analysis
  • Circuit Boards
  • Communication Systems
  • Control Panels
  • Detectors
  • Electronic Equipment
  • Engineering
  • Engineers
  • Failure Mode And Effect Analysis
  • Navy
  • Plastic Explosives
  • Power Distribution
  • Printed Circuit Boards
  • Printed Circuits
  • Silicon Controlled Rectifiers
  • Speed Regulators
  • Test And Evaluation

Readers

  • Electrical Engineering
  • Naval Architecture and Marine Engineering.
  • Systems Analysis and Design