Hydrophone for Low Frequency, Low Level Underwater Sound Measurements.
Abstract
This memorandum presents the design and performance characteristics of a hydrophone that is intended for low level noise measurements in the frequency range from 100 to 3000 cps. It is constructed of four barium titanate cylinders, each six inch O.D. by two inches long by 0.2 inch thick, that are mounted coaxially and mechanically isolated from each other and the end-plates.
Document Details
- Document Type
- Technical Report
- Publication Date
- Feb 02, 1961
- Accession Number
- ADA053115
Entities
People
- H. J. Clarke
- P. M. Kendig
Organizations
- Pennsylvania State University