Wisconsin Test Facility Ground Terminal Corrosion Study.
Abstract
Investigations of ELF ground system corrosion at the Navy's Wisconsin Test Facility were undertaken in response to concerns expressed by the National Academy of Sciences. Ground areas were excavated in several locations and the cable strand diameters measured for comparison with an unused cable. No evidence of corrosion in the ground system was observed. (Author)