State Variable Analysis of a Boiler System.
Abstract
The state variable formulation of a Foster Wheller ESD-III boiler is developed from fundamental principles. The response of the model for various input signals is determined using CSMP-III, the IBM simulation language. The sensitivity of the model to various coefficient values is noted as are the characteristics of various system states for small perturbation values. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1978
- Accession Number
- ADA055379
Entities
People
- Chusakdi Senanikrom
Organizations
- Naval Postgraduate School