Turbine Tip Clearance Measurement.
Abstract
Turbine tip clearance design and prediction techniques have been limited to analytical methods for lack of an accurate direct measurement device. It was the purpose of this program to substantiate prediction correlations utilizing direct measurements from a laser-powered miniaturized turbine tip clearance device (MTCMD) previously developed under Applied Technology Laboratory support. The resultant comparisons of measured versus analytically determined clearances based on measured temperatures would be used to verify or to improve the analytical techniques.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1978
- Accession Number
- ADA055765
Entities
People
- Gordon E. Grady
- Hagen R. Mauch
- Lawrence C. Baker
Organizations
- General Electric