Seismic Risk for Rush Valley, Utah and an Earthquake Design Analysis of Ammunition Storage Facilities for the South Area of Tooele Army Depot.

Abstract

This report contains analysis covering the methods used to estimate the average reoccurrence intervals for seismic events, analysis of ammunition storage structures in the Tooele Army Depot South Area, and the testing done on these storage structures as well as the Weteye bombs themselves. (Author)