Demilitarization Plan Operation of the Chemical Agent Munitions Disposal System (CAMDS) at Tooele Army Depot. Inclosure Number 15. Dunnage Incinerator Testing.
Abstract
An air pollution engineering source sampling survey was conducted at Tooele Army Depot to evaluate particulate and visible emissions from the Transportable Disposal System (TDS) dunnage incinerator with respect to standards of 0.2 gr/scf and No. 1 Ringlemann. The waste charging rate was 500 lb/hr. The measured particulate emissions for the two required test runs were 0.113 and 0.190 gr/scf. The observed visible emission was essentially zero on the Ringlemann Scale. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1977
- Accession Number
- ADA063622
Entities
People
- Robert L. Hanson