Improved Trace Oil Analysis Technique Using the Liquid Chromatographic Method with a UV detector.
Abstract
DREP has developed an improved method for measuring the trace amounts of oil in diver's air. The method includes the use of a Liquid Chromatograph with a variable wavelength ultra violet detector. The sample size for air can be reduced to 10 litres from 30 litres and the high degree of sensitivity of 0.2 of a microgram can be achieved. This method can also be used for the analysis of oil in water. (Author)