Eddy Current Testing and Ultrasonic Reference Standards for Depleted Uranium Barstock.
Abstract
The design and testing of ultrasonic test standards for one-half inch (12.7mm) diameter depelted uranium barstock is discussed. This report also explores the feasibility of testing the barstock for near surface flaws using an eddy current technique. It is shown that eddy current testing is the most efficient means available for detecting surface and near surface flaws in the barstock material. (Author)