National Dam Safety Program. Aquia Dam. Inventory Number: VA-17911. Potomac River Basin. Stafford County, Virginia. Phase I Inspection Report.

Abstract

Based upon the field conditions at the time of the field inspection and all available engineering data, the Phase I report addresses the hydraulic, hydrologic, geologic, geotechnic, and structural aspects of the dam. The engineering techniques employed give a reasonably accurate assessment of the conditions of the dam. It should be realized that certain engineering aspects cannot be fully analyzed during a Phase I inspection. Assessment and remedial measures in the report include the requirements of additional indepth study when necessary.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Feb 01, 1979
Accession Number
ADA073634

Entities

People

  • Paul Seiler

Tags

DTIC Thesaurus Topics

  • Computer Programs
  • Dams
  • Drainage Basins
  • Elevation
  • Embankments
  • Emergencies
  • Engineering
  • Field Conditions
  • Flow
  • Inspection
  • Photographs
  • Plastic Explosives
  • Potomac River
  • United States
  • Virginia
  • Visual Inspection
  • Warning Systems

Fields of Study

  • Engineering

Readers

  • Hydrologic Risk Analysis and Mitigation.