Finite Element Analysis of a Statically Loaded ISO Tactical Shelter

Abstract

A finite element analysis of a 2.4 m x 2.4 m x 6.1 m (8 ft x 8 ft x 20 ft) 3-for-1 expandable Army Shelter has been made for static loads designated in the specifications for Army ISO(International Standard Organization) Tactical Shelters. The report includes a description of the load paths, an investigation of the load-carrying capability of the structure both with and without wall panels as structural members, recommendations for improving the design for static load response, a buckling analysis for the ISO stacking test, and a comparison of calculated and measured data for a series of tests performed on the prototype shelter analyzed in this report.