High Contrast CRT.
Abstract
ERADCOM personnel successfully developed a method for sealing the 1720 glass faceplate to the 7052 funnel. The seal employs an intermediate region of uranium glass which is flame sealed to the funnel. Frit is used to seal the faceplate to the funnel. Two CRT's were successfully completed utilizing such a seal. Data taken on these tubes indicates a nominal peak line brightness of 10 fL in the red and 400 in the green at a writing speed of 5000 in/sec and a 60 hertz refresh rate.