Evaluation of the Effects of ASA-3 on the Performance of Military Standard Filter/Coalescer Elements.

Abstract

This report covers decontamination tests conducted on military standard filter/coalescer elements using JP-4 and JP-5 turbine fuels with and without antistatic additive ASA-3. During the tests, JP-5 with ASA-3 degraded filter/coalescer element performance. (Author)