Pershing PII Inertial Measurement Unit Calibration Trend Study.
Abstract
This report presents an overview of calibration data taken from Advanced Development Program Inertial Measurement Units. Behavior of calibration parameters is examined and worst/best performers are identified. Time trends are investigated by the method of linear least squares regression. Continued surveillance of parameters, determination of the effects of ill-behaved parameters on alignment and flight performance, and minimization of time required to perform a calibration are tasks to be performed during the Engineering Development program. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1980
- Accession Number
- ADA085944
Entities
People
- H. V. White
Organizations
- United States Army Aviation and Missile Command