A Modified Prony Method Approach to Echo-Reduction Measurements of Time- Limited Transient Signals
Abstract
A modified Prony method is presented for measuring the steady-state echo reduction of acoustic panels. The method extrapolates the steady-state amplitudes from the transient portion of the signal allowing time-limited measurements. The method is applied to measurements of square panels 76 cm on an edge and 0.95 cm-thick steel and aluminum in the frequency range of 3 - 10 kHz. The signals were time-limited to 200 microseconds (0.6 - 2.0 wavelengths) by the arrival of the diffracted signal from the panel edges. Results are compared with theoretical values and a program listing is included.
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 16, 1980
- Accession Number
- ADA087211
Entities
People
- David H. Trivett
Organizations
- United States Naval Research Laboratory