Experimental Studies of Annular (HSURIA) Resonators Including Polarization Effects.
Abstract
A repetitively pulsed CO2 laser facility was developed for testing annular resonators. The large-aperture device exhibits generally uniform gain over an annular region of 18-cm outer and 10-centimeter inner diameter. The half-symmetric unstable resonator with internal axicon (HSURIA) was tested at equivalent Fresnel numbers up to 4.5. This resonator design incorporates a W-axicon mirror beam compactor that transforms a cylindrical mode region into an annular mode region. Two HSURIA configurations were evaluated (1) with a rear conical mirror and (2) with a rear flat mirror in the annular leg. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 15, 1980
- Accession Number
- ADA089614
Entities
People
- E. B. Turner
- R. A. Chodzko
- S. B. Mason
Organizations
- The Aerospace Corporation