National Dam Inspection Program. Lake Hamilton Dam (NDI-ID Number PA-01031), DER-ID Number 64-157), Delaware River Basin, Wayne County, Pennsylvania. Phase I Inspection Report,

Abstract

Based on the visual inspection, past performance and the available engineering data, the dam and its appurtenant structures appear to be in fair condition. In accordance with the Corps of Engineers' evaluation guidelines, the size classification of this dam is small and the hazard classification is high. These classifications indicate that the Spillway Design Flood (SDF) should be in the range of one-half the Probable Maximum Flood (PMF) to the full PMF. The recommended SDF for this structure is the PMF. The spillway capacity is adequate for passing 51 percent of the PMF peak inflow without overtopping the dam. The spillway, therefore, is considered to be inadequate, but not seriously inadequate.