Temperature Sensitive Dynamic Cushioning Function Development and Validation for AIRCAP Cellular Polyethylene.

Abstract

This report describes the development of cushioning models for the AIRCAP cushioning material. The development models have been statistically validated and are available for use on the HP-9815A desktop calculator, or on a FORTRAN language computer. The temperature range of applicability is 32 F to 160 F and a static stress range of 0.03 to 0.80 psi. (Author)