Technical Data on KC-Film, Toners and Processes.

Abstract

The work accomplished includes measurements of the response of KC-Film, toners and processes. Data is included on charge levels, dark decay, voltage-log E response, reciprocity characteristics, as well as spectral sensitivity of KC-Film. This report includes grey scale responses for each of two toner types, including D-max and gamma ranges. Resolution capability is included as a function of toner types, surface voltage, toning time, exposure and image contrast. Resolution data is also provided as a function of time from imaging to toning. Granularity as well as acutance (edge sharpness) determinations are presented as a function of toner type. (Author)