Measurement of Performance Parameters for a FLIR Thermal Imaging System.
Abstract
The performance parameters of Noise Equivalent Temperature Difference (NETD), Minimum Resolvable Temperature Difference (MRTD), and Minimum Detectable Temperature Difference (MDTD) for the Naval Postgraduate School FLIR thermal imaging system were measured. The effects on these parameters of varying the detector aperture size (pinhole) were studied. It was determined that the thermal sensitivity of the system was directly proportional to the pinhole radius and resolution of the system was inversely proportional to the pinhole radius. Minimum values obtained were: NETD = 3.08 C, MRTD = 18 C, MDTD = 16 C. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jun 01, 1980
- Accession Number
- ADA092140
Entities
People
- William Lester Sellers
Organizations
- Naval Postgraduate School