Destroyer Engineered Operating Cycle (DDEOC) System Maintenance Engineering Analysis (SMEA) DD-963 Class 60/400 HZ Power Conversion and Distribution System SWAB Groups 314-4, 324-1, and 324-4 SMEA 963-314/324, Review of Experience,
Abstract
This report documents the historical and predicted maintenance experience for the DD-963 Class 60/400 Hz static frequency conversion and distribution system, SWAB groups 314-4, 324-1, and 324-4. It presents an analysis of the existing maintenance policy and the maintenance problems encountered and recommends specific actions and maintenance policy modifications to improve equipment availability, reliability, and maintainability. (Author)