At-Sea Test and Evaluation Of Oxygen (O2) Analyzers.
Abstract
This report presents the results, conclusions and recommendations derived from a continuous ten (10) month at-sea endurance test of eight (8) commercially available zirconium oxide boiler flue gas oxygen (O2) analyzers onboard the S. S. STELLA LYKES, a modern steam turbine propelled cargo vessel owned and operated by Lykes Brothers Steamship Company, Inc. Included within is a description of the program's purpose, objectives and scope. A discussion of the technical and economic merit and potential of continuously monitoring boiler flue gas oxygen content as an indicator of excess air being supplied for combustion is also presented. The program's background, requirements and technical approach are discussed in detail. The report includes the identification and recommendation of installation and service related requirements for the marine application of O2 analyzers. Finally, a recommended specification for a 'marinized' continuous reading zirconium oxide based oxygen analyzer has been developed and included in the report. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Apr 01, 1981
- Accession Number
- ADA098275