2 1/2 Hour Duration, Closed Circuit Life Support System Final Report Including Test Report and Outline for NIOSH Certification.

Abstract

A self contained, closed circuit breathing apparatus was developed for ILC DOver for the purpose of life support in a HCPCO (Hazardous Chemical Protective Clothing). Tests were performed to prove the design for life support compatibility over a duration period of 2.5 hours. Peripheral functions of the system were also tested. Recommendations were made from conclusive results. Finally an outline was presented for submitting the system for NIOSH certification. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Mar 31, 1981
Accession Number
ADA099763

Entities

People

  • M. A. Borrello
  • M. L. Kranz

Tags

DTIC Thesaurus Topics

  • Breathing Apparatus
  • Carbon Dioxide
  • Diameters
  • Engineering
  • Engineers
  • Failure Mode And Effect Analysis
  • Heat Exchangers
  • Life Support Systems
  • Machines
  • Manufacturing
  • Materials
  • Performance Tests
  • Pressure Transducers
  • Pressurization
  • Production
  • Protective Clothing
  • Quality Control

Readers

  • Aviation Safety Risk Assessment.
  • Exercise and Sports Science.