National Dam Safety Program. Baumgartner Dam (MO 10883), Missouri - Kansas City Basin, Callaway County, Missouri. Phase I Inspection Report.

Abstract

The purpose of the inspection was to make an assessment of the general condition of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicates that the spillway does meet the criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded and the large floodplain downstream of the dam, one-half of the Probable Maximum Flood is the appropriate spillway design flood. The spillway will pass the 100-year flood (flood having a one percent chance of being exceeded in any year) without overtopping the dam. The spillway will pass 50% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jun 01, 1979
Accession Number
ADA105540

Entities

People

  • Gordon Jamison
  • Harold P. Hoskins
  • Michael Mcmeekin
  • Rey S. Decker

Tags

DTIC Thesaurus Topics

  • Abstracts
  • Civil Engineering
  • Construction
  • Contractors
  • Contracts
  • Dams
  • Department Of Defense
  • Earth Fills
  • Engineering
  • Engineers
  • Inspection
  • Literature Surveys
  • Materials
  • Missouri
  • United States
  • Visual Inspection
  • Warning Systems

Readers