National Dam Safety Program. Purina Lake Dam (MO 31497), Missouri - Kansas City Basin, Franklin County, Missouri. Phase I Inspection Report.

Abstract

The purpose of the inspection was to make an assessment of the general conditions of the dam with respect to safety, based upon available data and visual inspection, in order to determine if the dam poses hazards to human life or property. The inspection and evaluation indicates that the spillways do not meet criteria set forth in the recommended guidelines for a small dam having a high hazard potential. Considering the small volume of water impounded and the downstream channel from the dam, one half of the Probable Maximum Flood is the appropriate spillway design flood. The spillways will pass the 100-year flood (1% probability flood - a flood having a one percent chance of being exceeded in any one year) without overtopping the dam. The spillways will pass 24% of the Probable Maximum Flood without overtopping the dam. The Probable Maximum Flood (PMF) is defined as the flood that may be expected from the most severe combination of critical meteorologic and hydrologic conditions that are reasonably possible in the region.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Oct 01, 1980
Accession Number
ADA105543

Entities

People

  • Garold Ulmer
  • Gordon Jamison
  • Harold P. Hoskins
  • Rey S. Decker

Tags

DTIC Thesaurus Topics

  • Concrete
  • Construction
  • Dams
  • Embankments
  • Engineering
  • Engineers
  • Inspection
  • Materials
  • Missouri
  • Photographs
  • Plastic Explosives
  • Ridges
  • Safety
  • Soils
  • United States
  • Visual Inspection
  • Warning Systems

Readers