Determination of Pyridine in Modified JP-4 VIA High Performance Liquid Chromatography (HPLC).

Abstract

A study was initiated to accurately determine the weight percent of pyridine present in pyridine-modified JP-4 used for contractual combustion studies. High Performance Liquid Chromatography (HPLC) was the method of choice. A chromatographic process was developed and systematic quantitative analyses performed to substantiate the accuracy and precision of the new test method. A computing integrator interfaced with the HPLC system performed all data collection and calculations automatically, with the results printed on a teletype. Least square curve fitting accentuated the reliability for determining pyridine in the 0.5 to 5.0 weight percent concentration range. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Apr 01, 1981
Accession Number
ADA105589

Entities

People

  • Paul C. Hayes Jr.

Organizations

  • Wright Laboratory

Tags

DTIC Thesaurus Topics

  • Accuracy
  • Aeronautical Laboratories
  • Air Force
  • Chlorides
  • Chromatography
  • Curve Fitting
  • Detectors
  • Flow Rate
  • Government Procurement
  • Governments
  • Hydrocarbon Fuels
  • Hydrocarbons
  • Integrators
  • Liquid Chromatography
  • Lubrication
  • Pyridines
  • Test Methods

Readers

  • Molecular and Cellular Biochemistry
  • Regression Analysis.
  • Systems Analysis and Design