Propellant Surveillance Report LGM-30 A, B, F & G Stage I TP-H1043 Aft Closur e Propellant.
Abstract
This report contains propellant test results from cartons of TP-H1043 propellant representing selected batches used in the aft closure of First Stage Minuteman Motors. Data from TP-H1043 propellant obtained from the aft closures of the LGM-30 A, B, F, and G Motors are reported in regression analyses for the sixth time and the fifth time using the G085 Computer System. In previous reports, A, B, F, and G data were combined for statistical analysis. For this report, a separate statistical analysis was made for A and B (wing 2) and F and G (wing 6). The statistical analysis includes regressions and covariance analysis. Testing was accomplished in accordance with MMWRBA Project M8293C. An analysis of all parameters indicate that no significant degradation is anticipated for at least two years past the oldest data point. Each point on the regression plot represents all samples at that particular age. The number of samples of each point is indicated on the sample size summary sheet on the page accompanying each regression plot. The data range at any age can be found by suitable inquiry of the G085 System. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1981
- Accession Number
- ADA107877
Entities
People
- John A. Thompson
Organizations
- Ogden Air Logistics Complex