National Dam Inspection Program. Pocono Highland Dam (NDI ID Number PA- 00992, DER ID Number 45-131), Delaware River Basin, Spring Run, Monroe County, Pennsylvania. Phase I Inspection Report

Abstract

Based on the criteria established for these studies, Pocono Highland Dam is judged to be unsafe, nonemergency, because the spillway capacity is seriously inadequate. The recommended Spillway Design Flood (SDF) for the size and hazard classification of the dam varies between 1/2 of the Probable Maximum Flood (PMF) and the PMF. The selected SDF is the 1/2 PMF. The existing spillway will pass only about 6 percent of the PMF before overtopping of the dam occurs. It is judged that the dam could not withstand the depth and duration of overtopping that would occur for the 1/2 PMF. If the low areas on the top of the dam were filled to the design elevation, the spillway would pass about 11 percent of the PMF without any overtopping. For either condition, the spillway capacity is rated as seriously inadequate. Failure of Pocono Highland Dam would cause an increased hazard for loss of life downstream.

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Jul 01, 1981
Accession Number
ADA109208

Entities

People

  • Frederick Futchko

Tags

DTIC Thesaurus Topics

  • Computer Programs
  • Computers
  • Concrete
  • Construction
  • Dams
  • Delaware River
  • Drainage Basins
  • Embankments
  • Engineering
  • Engineers
  • Geography
  • Housing (Dwellings)
  • Retaining Walls
  • Topography
  • United States
  • Visual Inspection
  • Warning Systems

Readers

  • Hydrologic Risk Analysis and Mitigation.