National Dam Safety Program. Kingsley Brook Reservoir Dam (Inventory Number N.Y. 353), Susquehanna River Basin, Madison County, New York. Phase I Inspection Report,

Abstract

This report provides information and analysis on the physical condition of the dam as of the report date. Information and analysis are based on visual inspection of the dam by the performing organization. Examination of available documents and visual inspections of the dam did not reveal conditions which constitute an immediate hazard to human life or property. However, the dam has some deficiencies that need to be evaluated and remedied. Using the Corps of Engineers' screening criteria for the initial review of spillway adequacy, it has been determined that the embankment would be overtopped by all storms exceeding 21 percent of the Probable Maximum Flood (PMF). Dam overtopping, the resulting erosion of the embankment and hence, dam breaching would cause water surface levels downstream to reach depths which would pose significant danger to residents. Therefore, the spillway is adjudged to be seriously inadequate and the dam is assessed as unsafe, nonemergency. The classification 'unsafe' applied to a dam because of a seriously inadequate spillway is not meant to connote the same degree of emergency as would be associated with an 'unsafe' classification applied for a structural deficiency. It does not mean that there appears to be a serious deficiency in spillway capacity and if a severe storm were to occur, overtopping and failure of the dam could take place, significantly increasing the hazard to life downstream of the dam. (Author)

Open PDF

Document Details

Document Type
Technical Report
Publication Date
Sep 15, 1981
Accession Number
ADA109794

Entities

People

  • Hugh C. Flaherty

Tags

Communities of Interest

  • Human Systems
  • Weapons Technologies

DTIC Thesaurus Topics

  • Climate Change
  • Concrete
  • Construction
  • Dams
  • Department Of State
  • Drainage Basins
  • Embankments
  • Engineering
  • Engineers
  • Gate Valves
  • Insensitive Explosives
  • Materials
  • Mechanical Equipment
  • New York
  • Plastic Explosives
  • Visual Inspection
  • Warning Systems

Readers